QUESTIONS AND ANSWERS FOR THE 3V0-21.23 EXAM, AUTHENTIC 2025

Questions and Answers for the 3V0-21.23 Exam, Authentic 2025

Questions and Answers for the 3V0-21.23 Exam, Authentic 2025

Blog Article

Tags: New 3V0-21.23 Dumps Ppt, Exams 3V0-21.23 Torrent, 3V0-21.23 New Study Guide, 3V0-21.23 Vce Download, Premium 3V0-21.23 Files

We value every customer who purchases our 3V0-21.23 test material and we hope to continue our cooperation with you. Our 3V0-21.23 test questions are constantly being updated and improved so that you can get the information you need and get a better experience. Our 3V0-21.23 test questions have been following the pace of digitalization, constantly refurbishing, and adding new things. I hope you can feel the 3V0-21.23 Exam Prep sincerely serve customers. We also attach great importance to the opinions of our customers. As long as you make reasonable recommendations for our 3V0-21.23 test material, we will give you free updates to the system's benefits. The duration of this benefit is one year, and 3V0-21.23 exam prep look forward to working with you.

VMware 3V0-21.23 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Plan and Design the VMware Solution: This part targets Solution Designers, evaluating their ability to gather business objectives, create conceptual models based on these objectives, develop logical designs, and translate them into physical designs that meet specific requirements like manageability or security.
Topic 2
  • VMware Products and Solutions: Targeting VMware Engineers, this section describes VMware Cloud Foundation architecture, its components like vSphere and NSX, benefits such as automation and scalability, and use cases like hybrid cloud environments. It assesses understanding of VMware Validated Solutions.
Topic 3
  • IT Architectures, Technologies, Standards: This section of the exam measures the skills of IT Architects and covers differentiating between business and technical requirements, as well as conceptual, logical, and physical design. A key skill measured is "Designing System Availability."

>> New 3V0-21.23 Dumps Ppt <<

First-grade New 3V0-21.23 Dumps Ppt - 100% Pass 3V0-21.23 Exam

Our PDF version, online test engine and windows software of the VMware vSphere 8.x Advanced Design study materials have no restrictions to your usage. You can freely download our PDF version and print it on papers. Also, you can share our 3V0-21.23 study materials with other classmates. The online test engine of the study materials can run on all windows system, which means you can begin your practice without downloading the 3V0-21.23 Study Materials as long as there have a computer. Also, our windows software support downloading for many times. What is more, you can install our 3V0-21.23 study materials on many computers. All of them can be operated normally. The three versions of 3V0-21.23 study materials are excellent. Just choose them as your good learning helpers.

VMware vSphere 8.x Advanced Design Sample Questions (Q34-Q39):

NEW QUESTION # 34
What is the purpose of determining business continuity requirements for a vSphere design?

  • A. To optimize the system's data storage and retrieval processes.
  • B. To specify the expected levels of system performance and responsiveness.
  • C. To identify the virtual machines and cores needed for the vSphere environment.
  • D. To ensure uninterrupted business operations in case of disruptions or failures.

Answer: D


NEW QUESTION # 35
An architect is responsible for extending the hosting design for a customer. The customer has a mission- critical 3-node application which is load balanced in an active/active/passive configuration. The application administrator requests that the virtual infrastructure team be responsible for maintaining platform level availability. An organizational policy exists to mandate the highest possible availability for mission-critical applications.
Based on the resource requirements, the architect has made the following design decision:
The target vSphere cluster contains three VMware ESXi host servers
A combination of which additional four physical design decisions should the architect make to maximize availability of the application? (Choose four.)

  • A. The solution will create a VM-VM Affinity rule to keep virtual machines separate.
  • B. The solution will create a VM-VM Affinity rule to keep virtual machines together.
  • C. The solution will enable vSphere Fault Tolerance with vSphere High Availability (HA) virtual machine component failure enabled.
  • D. The solution will enable vSphere High Availability (HA) with restart priority set to "Highest" for the application virtual machines.
  • E. The solution will create a VM-Host Affinity rule that specifies that workloads must run on hosts in a group.
  • F. The solution will create a virtual machine DRS group that contains all of the critical application workloads.
  • G. The solution will create a host DRS group containing all hosts within the cluster.

Answer: C,D,E,F

Explanation:
The solution will create a VM-Host Affinity rule that specifies that workloads must run on hosts in a group.
Creating a VM-Host Affinity rule ensures that specific workloads are restricted to certain hosts, which can be useful to avoid placing critical applications on hosts that may not meet their availability requirements.
The solution will enable vSphere High Availability (HA) with restart priority set to "Highest" for the application virtual machines.
Enabling vSphere HA ensures that virtual machines are automatically restarted on other hosts in the event of a host failure. Setting the restart priority to "Highest" for mission-critical VMs ensures that these VMs will have the highest priority for restart if any issues arise.
The solution will enable vSphere Fault Tolerance with vSphere High Availability (HA) virtual machine component failure enabled.
Enabling vSphere Fault Tolerance (FT) ensures that the application VMs are fully protected by creating a live shadow VM that runs in lockstep with the primary VM. In the event of a host failure, the shadow VM will take over instantly, providing continuous availability for the application.
The solution will create a virtual machine DRS group that contains all of the critical application workloads.
Creating a virtual machine DRS (Distributed Resource Scheduler) group for critical workloads ensures that these VMs are placed and migrated to the optimal hosts based on the cluster's resource requirements, improving availability and performance.


NEW QUESTION # 36
A VMware Service Provider is tasked with delivering a solution for continuous availability for a subset of Tier 1 virtual machines (VMs) and vApps running in their vSAN environment. The VMs make up a mission-critical application and there can be no data loss in the event of an outage at their primary data center. In the event of a regional outage, they have established a 10-minute recovery point objective (RPO). Failover/failback to the third site must be automated.
They have the following in place:
- Two local data centers (primary and secondary) connected with 100 Gb dedicated fiber
- 2ms round-trip time (RTT) latency between the sites
- A third data center located on another power grid
- 70ms latency between the primary and secondary data centers
- Matching storage arrays at all locations
Which two solutions could be used to meet the requirements- (Choose two.)

  • A. vStorage APIs for Array Integration (VAAI)
  • B. vSAN Metro Cluster
  • C. vSphere Data Protection
  • D. Snapshots
  • E. Site Recovery Manager

Answer: B,E

Explanation:
Metro is a stretched-cluster, vSAN tolerates 5ms to main sites first-second and 150ms to a third site where a witness vm will stay, all details are correct till now. Matching storage arrays at all locations seems to be, or its a single datastore presented to infrastructure itself. As the third site has an infrastructure established as well can be used to replicate VMs from the stretched datastore from first-second, the need of Site Recovery.


NEW QUESTION # 37
An architect is tasked with designing a new VMware software-defined data center (SDDC) using VMware vSAN. The architect uses a storage assessment tool to determine the storage requirements for the new vSAN cluster. The new SDDC is going to be deployed into the existing data center and must be connected to a shared core network switch.
The architect decides to use vSAN ReadyNodes with the following configuration:
Two disk groups with:
- Write Intensive NVMe 800 GB drive for cache
- Four 3.84 TB Mixed Use NVMe for capacity
- Four 10 GbE ports
Which element represents a risk that should be included in this design?

  • A. The existing network is 10 GbE capable
  • B. The use of NVMe drives for cache and capacity
  • C. The number of 10 GbE capable ports in the vSAN ReadyNode
  • D. The use of vSAN ReadyNodes

Answer: A


NEW QUESTION # 38
An architect is designing a new vSphere cluster. The requirement is to provide a total of 96 CPU cores and 1.5 TB RAM across all hosts.
The following information has been provided:
1. Two different physical hardware profiles are available for the ESXi hosts in the cluster.
- Profile 1: 16 CPU cores and 256 GB RAM
- Profile 2: 32 CPU cores and 512 GB RAM
2. Profile 2 is twice as expensive to purchase as Profile 1.
Which two aspects should the architect consider when selecting the hardware profile? (Choose two.)

  • A. The number of virtual machines that will be running within the cluster
  • B. The downtime allowed for virtual machines that will be running within the cluster
  • C. The cost to procure and maintain the hardware
  • D. The manufacturer and model of the CPUs in the hosts
  • E. The amount of capacity available for failover of virtual machines within the cluster

Answer: A,E


NEW QUESTION # 39
......

We provide free updates of our 3V0-21.23 exam questions to the client within one year and after one year the client can enjoy 50% discount. If clients are old client, they can enjoy some certain discount. Our experts update the 3V0-21.23 guide torrent each day and provide the latest update of our 3V0-21.23 Study Guide to the client. We provide discounts to the client and make them spend less money. If you are the old client you can enjoy the special discounts thus you can save money. So it is very worthy for you to buy our 3V0-21.23 test torrent.

Exams 3V0-21.23 Torrent: https://www.dumpsmaterials.com/3V0-21.23-real-torrent.html

Report this page